| Conditioning
Modules |
| The M1000 accepts sensor inputs
and provides amplification for most of todays test requirements. This is
accomplished with a standard set of input and output modules. Modules are compatible with
laboratory and portable chassis or the new M4000 field data
acquisition PC to minimize investments in equipment and training while maximizing use.
Modules are available for LVDT, RVDT, strain gage, synchro or resolver, thermocouple, RTD,
potentiometer, piezo resistive accelerometer or pressure transducer, encoder and other
types of frequency inputs, etc. High voltage input and cold junction are provided
optionally. Amplifiers are available to provide gain or attenuation, RMS and isolation.
Most modules will provide dual separately adjustable outputs of voltage or current. |
 |
 |
 |
| ·
Input Modules · · · |
|
M1060 High Gain DC Amplifier
Differential amplifier for use with most types of low level transducers (strain gage,
load cells, etc.). Fine gain control is provided up to 2000.M1064 Wide Bandwidth
Gain Amplifier
Differential amplifier for use with wide bandwidth, dynamic sensors and signals.
Offers wide zero control range making this module an excellent choice for piezo resistive
and other sensors requiring this.
M1060 Thermocouple Amplifier
For use with thermocouples and similar low level sensors. Adjustable cold junction
sensitivity. Full scale output for 1 mV to 100 mV input. The optional M1061/R Reference
Connector provides a cold junction.
M1080 Frequency/DC Converter
For use with turbine flowmeters, rpm, speed angular position pickups and sensors, this
pulse to signal converter offers adjustable ranges, input signal conditioning and input
voltage ranges up to 250V when used with the optional C103 or C104 high voltage input
connector. |
|
M1070 Attenuator/Amplifier
General purpose differential input module for medium to high level signal inputs
(potentiometric sensor inputs, LVDT/RVDT, servo accelerometer, general attenuation or
amplification needs). Offers sensor excitation and fine gain or attenuation control over
+/-2 decades.M1079 Isolated Attenuator/Amplifier
Similar to the M1070 with the addition of galvanic isolation
M1049 Carrier Amplifier
Carrier Amplifier (Oscillator/Amplifier-Demod/Filter) for use with variable
reluctance, piezo resistive and torque transducers, LVDT/RVDT, and strain gage based
sensors.
M1043 Synchro/DC Converter
Provides a DC output signal proportional to synchro or resolver angular position
inputs. Applications include CNC machine tools, gyros, radar position. C103 or C104 High
Voltage Input Connector Expands the module voltage input range to 250V. |
 |
| ·
Output Modules · · · |
|
Certain chassis, indicated by a /P
designation, offer output conditioning slots. These slots must be filled by one of the
following cards: |
|
M1088 Channel Completion CardM1091-01-P Active Filter (Bessel)
M1089-P Designers card
M1090-01-P Active Filter (Butterworth) |
|
M1072-P Power AmplifierM1092-01-P Active Filter (Tchebyshev)
M1015-P/01 Isolated DC transducer excitation supply
M1095-P Linearizer |
 |
| Customized
Conditioning |
|
Over many years, we
have built up a library of custom 'specials', many of which can be tailored to individual
requirements. Alternatively, we are always happy to look at non-standard signal
conditioning, if a standard amplifier is not available. |

|
|